Veterinary Sterilization Laboratory Autoclave With Visually And Audibly Alarm
Brief
This Autoclave Steam Sterilizer is designed to sterilize veterinary instruments from veterinary
laboratories, veterinary quarantine station, epidemic prevention station , livestock farm and animal
hospitals etc.
Designed and manufactured according to ISO 9001, ISO 13485 system and latest moist steam
sterilizer related standards, which has the obvious advantage of low failure rate and easily
operation to ensure your satisfied using smoothly.
Safety
Door Safety
• Chamber door cannot be opened when chamber is pressurized
• Steam cannot enter the chamber when the door is open
• A cycle cannot start if the door is open or not properly locked
• Sliding door movement is stopped if an object is detected in front of the door
Safety Valves
• Both chamber and jacket are equipped with pressure relief valves to prevent excess pressure.
• Saturated steam can be supplied to the autoclave from building steam equipped safety valve
• A stand-alone generator or a built-in steam generator with safety valve is available for your option
Emergency Shut-Off
• Easily accessible emergency switches for immediate cycle shut-off.
• Double Independent Monitoring
• Digital and mechanical monitoring systems provide accurate pressure results which are displayed
on the analog and digital displays.
Sterilization Programs
1, B-D Test
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.
2, Vacuum Leak Test
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.
3, Instruments/Tools
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.
4, Clothing
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.
5, Liquid
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min.
6, User Programmable
All preset parameters can be resettable; total 15 kinds programs can be customized
Loading/Unloading System
Standards equipped: 1 piece loading cart of SUS316L stainless steel, 1 piece trolley of SUS304
stainless steel for single door sterilizer and 2 pieces trolley for double door.
Loading plate, racks or shelves are available for option.
All loading/unloading system features of,
• High capacity for maximum throughput
• Eliminates operator handling of hot loads
• Swivel casters for easy maneuverability
• Low profie docking mechanism for easy alignment
• Racks and shelves for selected chamber sizes
Main Parameters
Model |
MD-0.6V |
Door type |
Vertical sliding single/double door |
Max working pressure |
0.23Mpa |
Working vacuum degree |
<-0.086Mpa |
Max working temperature |
134℃ |
Chamber size |
1670*600*600 mm(L*W*H) |
External dimension |
2010*1350*1800mm(L*W*H) |
Net weight |
1200Kg |
Utilities Supply |
|
Electric power |
AC380V, 50Hz, 3Ph/N/E,3KVA |
Water |
0.15---0.3MPa, Hardness <50ppm, pH Neutral, 55Kg/cycle |
Steam |
0.5~0.7Mpa, 30Kg/cycle |
Compressed air |
0.5~0.7Mpa, 10 liters/minute |