Product Details:
Payment & Shipping Terms:
|
Chamber Volume: | 1200 Liters | Chamber Material: | AISI 316 |
---|---|---|---|
Door Number: | Single Or Double | Door Type: | Motorized Hinge Door |
Feature: | Flexible Loading System | Application: | Medical Instruments |
High Light: | auto clave machine,medical sterilizer machine |
Pre Heated Autoclave Sterilizer Machine With Emergency Exhaust Switch And Safety Valve
Features
Specifications
Model |
MD-1.2 |
Door number |
Single or double door |
Door type |
Motorized Hinge Door |
Chamber volume |
1200 liters |
Chamber Size |
680*1180*1500mm |
Overall Size |
1600*2000*1840mm |
Net Weight |
1950kg |
Steam |
45Kg/cycle |
Water |
120Kg/cycle |
Power(KVA) |
4KVA |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Steam feeding |
Steam pressure: 0.4---0.7MPa |
Water |
Water pressure: 0.15----0.3MPa |
Compressed air |
Compressed air pressure: 0.5---0.8MPa |
Description
The new, recently designed sterilizer was created through careful selection of materials, components and technical solutions that ensure durability, productivity and functional safety at every moment.
All of our machines are constructed according to a high standard of reliability and hygiene.
Construction
Chamber |
Rectangular, with central crease and drop. The existing piping under the covering protection is in AISI 316 Stainless steel . |
Jacket |
Built in AISI 304 Stainless steel , Chamber is tested with hydrostatic pressure equal to 1.5 times the project pressure. |
Piping |
Manufactured in Stainless steel AISI 316 or AISI 304 . The piping also has thermal insulation to avoid heat loss . |
Chamber support structure |
Adjustable feet allow leveling system and optionally casters for displacement. |
Two independent validation inlets |
Located on the lateral side of the chamber, allows introduction of sensors for process temperature data collection. |
Chamber drain |
Protected with 1 ½” diameter filter in perforated stainless steel plate. Located from the flange of the non-sterile door side. |
Doors |
Doors movements through a pneumatic cylinder, without counterweight, with an anti-crush sensor and calibrated clamping force.The door has internal side in stainless steel AISI 316L (optionally in AISI 316 ) with sanitary polishing finish |
Silicone gasket |
Round, activated by compressed air to maintain the tightness of the door during the ste-rilization process. |
Contact Person: Ms. Juliet