Product Details:
Payment & Shipping Terms:
|
Door Type: | Motorized Hinge Door,double Door | Application: | Medical Centers |
---|---|---|---|
Feature: | Advanced Control System | Sterilization Temperature Rage: | 105°C To 134°C |
Chamber Volume: | 0.6m3 | Sterilization Time Rage: | 0---99 Minutes |
High Light: | medical sterilizer machine,sterile medical equipment |
High Temperature Resistant Silicon Rubber Autoclave Sterilizer Machine With Door Process Lock and Interlocking
Features
• An advanced, PC-based control system employs user friendly interface screens, with enhanced graphics.
• Color touch screen display.
• Ink on paper impact printer.
• Standard communication interface with most PC-compatible peripheral devices (e.g., data collection systems, printers)
• Automatic check of control program and cycle data maintains process integrity
• Control is designed to accommodate integrated
Specification
Model |
MD-0.6 |
Door type |
Double door type |
Door open method |
Motorized Hinge Door |
Chamber volume |
600L |
Chamber Size |
610*910*1170mm |
Overall Size |
1500*1900*1510mm |
Net Weight |
1250kg |
Steam |
30Kg/cycle |
Water |
60Kg/cycle |
Power(KVA) |
3KVA+24Kw for steam generator |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Components |
SS304 built-in steam generator |
Touch screen display |
|
PLC control system |
|
High effective liquid-ring vacuum pump |
Applications
This series hospital sterilizer are designed and manufactured specially for hospital CSSD,
operating room to sterilizing medical instruments, sterile clothing, dressings, vessels,
apparatuses, operating tools, culture medium etc.
Control system
Design Features |
The control system monitors and controls all sterilizer operations and functions. |
The control system is factory programmed |
|
All operator-accessible control functions can be changed using the touch screen control |
|
Uninterruptable Power Supply (UPS) |
In event of main power failure to the sterilizer, a UPS provides backup power. |
Operator interface control panel |
Consisting of a touch screen, is located on the operating end of the sterilizer. |
24-Character ink-on-paper printer |
Located below touch screen, provides an easy-to-read printed record of all pertinent cycle data on wide paper |
Non-operating end (NOE) control panel |
On double-door sterilizers only, includes a touch sensitive screen similar to the operating end screen. |
Preprogrammed cycles can be started from the NOE control panel. Display concurrently shows the same information as the operating end screen display |
|
Cycle configuration |
Performed by accessing the Change Values menu through the operating end touch screen. |
Time display and printout units |
24-hour or AM/PM. |
end-of-cycle signals and alarm signals |
Adjustable volume levels available through the |
Pressure/vacuum display and printout units |
psig/InHg or bar. Recalibration is not required when changing pressure units. |