Contamination seal Autoclave Sterilizer Machine With Air Intake Filter And Pressure Switches
Features
Description
Medpharm offers a wide selection of saturated steam sterilizers to exceed industry standards,
available in single or pass-through versions, with hinged or sliding doors . Built to a very high
standard,each unit is tailored to the customer’s individual specifications.
Medpharm is able to offer an extremely diversified product range capable of meeting the
requirements of the most varied applications and satisfy the strict standards of the Laboratory
and research.
Main parameters
Model | Chamber Size | Overall Size | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg/cycle | Kg/cycle | KVA | |
MDL-0.24 | 600*600*670 | 1500*1800*1010 | 20 | 30 | 2 |
MDL-0.36 | 600*600*1000 | 1500*1800*1340 | 25 | 40 | 2 |
MDL-0.6 | 610*910*1170 | 1500*1900*1510 | 30 | 60 | 3 |
MDL-0.8 | 610*910*1450 | 1500*1900*1790 | 35 | 80 | 3 |
MDL-1.0 | 680*1180*1250 | 1600*2000*1590 | 40 | 100 | 4 |
MDL-1.2 | 680*1180*1500 | 1600*2000*1840 | 45 | 120 | 4 |
MDL-1.5 | 680*1180*1870 | 1600*2000*2210 | 50 | 150 | 4.5 |
Materials optional
MATERIALS | ||
Chamber | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Jacket | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Door internal side | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
|
Advanced Control system
The microprocessor-based controller is provided with preprogrammed cycles to meet most laboratory requirements.
The controller interface is designed to permit easy user access and simplified one-motion start function. Multiple displays are arrayed on the graphic user interface to clarify cycle selection and real-time performance through plot, detail and line graph expression.
Sterilization and Test Cycles
Vacuum Cycles: Cycles selected for sterilization of nonliquids are programmed to force removal of ambient air trapped within the load through initiation of a vacuum sequence. Time sequencing and duration of individual phases is tailored to the preset determination.
Liquids Cycles: Cycles selected for sterilization of vented liquids are designed to slow the rate of exhaust to prevent boilover as chamber pressure is returned to atmospheric Pressure.
Test Cycles: Individual test cycles are preprogrammed in accordance with standard best practices to verify the efficacy of the sterilizer and its performance.
Bowie-Dick Test: The Bowie-Dick test is a widely accepted process to assure that ambient air has been properly removed from the chamber and load, prior to sterilization.
Vacuum Leak Test: The integrity of the sterilizer chamber and associated plumbing, both under pressure and vacuum, is verified by running a vacuum leak test as directed by local lab safety or facilities management officers.