Product Details:
Payment & Shipping Terms:
|
Product Name: | Hospital Sterilizer | Sanitary Process Piping: | Standard Feature |
---|---|---|---|
Steam Generators: | Standard Feature | 0.22um Membrane Type Sterilizing Grade Air Admission Filter: | Standard Feature |
Door Type: | Vertical Sliding Door | ||
Highlight: | Medical Sterilization Equipment,Medical Instrument Sterilizer |
Fully Automatic Dual Control Hospital Sterilizer With Accurate Temperature Sensor And Pressure Transducer
Specification
The control system for hospital steam sterilizers features enhanced functionality and
user-friendly interface screen.
• Ink-on-paper impact printer
• Help screens for programming and trouble shooting alarm conditions
• Automatic check of control program and cycle data maintains process integrity
• Service reprogrammable flash ROM memory
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.16V |
400*400*1000 |
1200*1800*1340 |
700 |
16 |
20 |
2 |
Program Parameter
Cycle name |
Further details |
Application |
Instruments/Tools |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
Solid materials to be sterilized: ●Packaged instruments ●Empty glass containers ●Empty metal containers Porous materials to be sterilized: ●Rubber articles |
Clothing |
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
Materials to be sterilized from which air can’t be easily displaced ●Textile |
User Programmable |
All preset parameters can be reset; Multiple customized programs can be set and stored by user. |
Customized |
Test programs |
||
B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
Test program |
Vacuum Leakage Test |
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
Test program |
Description
The hospital sterilizers are designed for fast, efficient sterilization of heat- and moisture-stable
materials in addition to sterilization of items for immediate use.
Each hospital sterilizer is equipped with either a single or double door, for open or
recessed mounting.
Hospital sterilizers are equipped with pre-vacuum, gravity, leak test, and daily air removal test cycles.
Competitive Advantage
Control senses when door seal is closed and sealed, preventing cycle start until a limit switch
signal is received. If control loses appropriate signal during cycle, alarm activates, cycle aborts and chamber safely vents with a controlled exhaust.
Chamber Float Switch activates alarm, aborts cycle and safely vents chamber with a controlled
exhaust if excessive water is detected in the vessel chamber.
Pressure Relief Valve limits the amount of pressure buildup so that the rated pressure in the vessel is not exceeded.