Product Details:
Payment & Shipping Terms:
|
Product Name: | Large Steam Autoclave | Operation Interface: | PLC |
---|---|---|---|
Safety Valve: | Integral To The Plumbing | Door Open: | By Motor |
Door Close: | Electric Door Switch | Sterilization Cycle: | B-D Test, Liquid, Solid, |
Sterilization Results: | F0 Value | Air Filter: | Accuracy 0.22um |
Highlight: | Veterinary Medical Devices,Veterinary Clinic Equipment |
Bulk Veterinary Autoclave With Integrated Micro Computer Controlled For Animal Cages
Brief
Medpharm V series sterilizers are designed for sterilization of materials used in healthcare facilities, veterinay laboratory and veterinay pharmaceutical factory. It uses steam as sterilization medium and is designed for fast, efficient sterilization of heat and moisture stable materials and immediate use. It is equipped with pre-vacuum, gravity, leak test and daily air removal test cycle.
Features
The chamber is rectangular chambers eliminate the wasted space and vertical door occupies
less floor space and provides greater capacity. The door is fully automatic in operation and is
raised and lowered by motor. Door operation is controlled via pushing buttons on the control
panel then the door is sealed automatically.
Door safety
Electric door switch ensures the door is fully closed and locked prior to the cycle start. Cycles
can't start until the door(s) are fully closed and locked. The door can’t be open during cycles or
pressure in the chamber exceeds 0.15 bar.
The electro-mechanical lock on each door minimizes the chance of cross-contamination
between contained and uncontained areas by preventing both doors from being operated
simultaneously.
The gasket is strong pressed against the rear face of the door by compressed air at the beginning and at the end of the process, the gasket is retraced by vacuum and the door on the unloading side is opened by motor with gear.
Chamber and Jacket
Control System
Cycles
Cycle Name |
Program preset details |
Sterile products for reference |
Instruments/Tools |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
instruments with narrow tube, Filters, Biology glassware, dental instruments, disassembled filter housings, animal cages |
Clothing |
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
lab coats, hospital bedding, gauze |
Liquid |
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. |
Medicine powders, mushroom substrate, cultures, vaccine, ampoules and vials |
B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
B-D package |
Vacuum Leakage Test |
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
Test air leakage. Start before sterilization cycle. |
User Programmable |
All preset parameters can be reset; Multiple customized programs can be set and stored by user. |
Defined by customers special requests besides the preset programs. |
Printer
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400