Product Details:
Payment & Shipping Terms:
|
Volume: | 200 Liters | Sterilization: | Large Steam Autoclave |
---|---|---|---|
Installation: | Recessed Through Wall Or Floor Standing | Door Qty: | Pass Through Or Single Door |
Door Open: | Vertical Sliding Automatically | Application: | Medical Waste,vented Substrate,instruments And Fabric |
Chamber Size: | 40*40*130cm | Outer Size: | 100*180*164cm |
Highlight: | Medical Waste Autoclave,Healthcare Sterilizer |
Rectangular Single Ended Construction Large Steam Sterilizer With Visually And Audibly Alarm
Chamber Design
1. The sterilizer chamber, jacket and door are made from solid, high quality type AISI316 L/ W.Nr.1.4404 stainless steel.
2. Internal surfaces are treated with glass blasting to facilitate cleaning.
3. The sterilizer chamber is completely insulated with a 30-80 mm chloride free mineral wool, encased in a rigid removable aluminum sheet housing.
4. The chamber is mounted on a stainless steel framework with adjustable feet.
Automatic vertically sliding door
1. The door is fully automatic in operation and is raised and lowered by a motor. Door operation is controlled via push buttons on the control panel.
2. The door is automatically sealed. Doors can not be open during the cycle. The gasket is
a silicon rubber ring. In the beginning of a process, the gasket is pressed against the rear face of the door by air.
3. At the end of the process, the gasket is retracted by vacuum and the door on the unloading
side is opened by a motor with gear box.
Personnel safety
In addition to the door safety systems, the chamber is provided with a pressure monitoring system that ensures that all chamber pressure has been relieved prior to allow the door(s) to open. The fascia temperature never exceeds 55 °C.
Vacuum pump
A highly efficient liquid ring vacuum pump, mounted on vibration isolators for quiet operation,
is provided to effectively remove air from within the chamber. The vacuum pump is connected
in series to assist air removal and protect the vacuum pump from excessive temperatures.
Air filter
Air filter is provided, for filtering of atmospheric air, entering the chamber. Air is used to equalize the chamber pressure at the end of the sterilization cycle. The filter separation efficiency is higher than 99,998% for particle size max. 0,22μm.
Valves
All process valves are pneumatically operated piston valves, providing longer service life and less maintenance. All standard components are non-proprietary and easily sourced. All piping and valves are made of stainless steel.
Main Parameters
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.11V |
400*400*700 |
1000*1800*1040 |
650 |
14 |
15 |
2 |
MD-0.16V |
400*400*1000 |
1000*1800*1340 |
700 |
16 |
20 |
2 |
MD-0.20V |
400*400*1300 |
1000*1800*1640 |
750 |
18 |
25 |
2 |
MD-0.24V |
600*600*670 |
1200*2000*1010 |
800 |
20 |
30 |
2 |
MD-0.30V |
600*600*840 |
1200*2000*1180 |
850 |
22 |
35 |
2 |
MD-0.36V |
600*600*1000 |
1200*2000*1340 |
900 |
25 |
40 |
2 |
MD-0.45V |
600*600*1250 |
1200*2000*1590 |
980 |
27 |
50 |
2 |
MD-0.60V |
600*600*1670 |
1200*2000*2010 |
1100 |
30 |
60 |
3 |