Product Details:
Payment & Shipping Terms:
|
Application: | CSSD | Test Programs: | Bowie & Dick Test, Vacuum Test |
---|---|---|---|
Door Construction: | Horizontal Sliding Door | Temperature Rage: | 105 --- 134°c |
Cofiguration: | Floor-Standing | Feature: | High Capacity |
High Light: | medical waste sterilizer,Autoclave Medical Instruments |
CSSD Pit Mount Double Door Autoclaves With Horizontal Sliding Door
Key Features
Chamber volume range is from 800 to 8000 liters
Chamber and process piping made of stainless steel AISI304
Horizontal sliding door made of stainless steel for durability and ease of cleaning
Suitable for floor level installation
Direct and indirect steam to steam feed versions
Easy service with frontal access
5.7” touch screen panel HMI
Integrated Ink paper printer
For CSSD ,OR ,medical centers applications
Main Parameters
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.8Y |
680*1180*1000 |
2200*2000*1410 |
1480 |
35 |
80 |
3 |
MD-1.0Y |
680*1180*1250 |
2200*2000*1660 |
1630 |
40 |
100 |
4 |
MD-1.2Y |
680*1180*1500 |
2200*2000*1910 |
2030 |
45 |
120 |
4 |
MD-1.5Y |
680*1180*1870 |
2200*2000*2280 |
2230 |
50 |
150 |
4.5 |
MD-2.0Y |
1000*1200*1700 |
2800*2000*2110 |
2490 |
60 |
200 |
4.5 |
MD-3.0Y |
1000*1500*2000 |
2800*2200*2410 |
3050 |
90 |
300 |
5 |
MD-4.0Y |
1000*1500*2670 |
2800*2200*3080 |
3700 |
120 |
400 |
6 |
MD-5.0Y |
1000*1500*3340 |
2800*2200*3750 |
4600 |
150 |
500 |
8 |
MD-6.0Y |
1000*1500*4000 |
2800*2200*4410 |
5400 |
180 |
600 |
8 |
MD-8.0Y |
1000*1500*5340 |
2800*2200*5750 |
7000 |
240 |
800 |
12 |
Sterilization Cycles
The steam autoclaves provide a variety of sterilization cycles for the sterilization surgical instruments, utensils, gowns, wrapped/unwrapped goods and other healthcare instrumeand supplies.
Cycle No. |
Cycle Name |
Further Details |
1 |
Instruments/Tools |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
2 |
Clothing |
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
3 |
Liquid |
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. |
4 |
B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
5 |
Vacuum Leak Test |
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
6 |
User Programmable |
All preset parameters can be resettable; Multiple customized programs can be set and stored by user. |
The Autoclaves Advantages
Easy To Operate
Process Documentation
Minimized Service
The sterilizer is designed with few components and equipped with the software, making service and maintenance very simple. Connections for external independent temperature sensors for validation, as well as connections for PC, are part of the system.