Product Details:
Payment & Shipping Terms:
|
Chamber Capacity: | 800 Liters | Chamber Material: | AISI 316 |
---|---|---|---|
Door Number: | Single Door | Door Type: | Motorized Hinge Door |
Display Panel: | Colour Touch Screen | Temperature Control: | Available |
Highlight: | High Pressure Steam Sterilizer,Table Top Autoclave Steam Sterilizer |
800 Liters Autoclave Steam Sterilizer With Temperature Control Pressure Control
Sterilizer details:
Application |
For CSSDs and OR applications |
Chamber material |
316L stainless steel chamber |
Chamber volume |
800 Liter chamber volume |
Display panel |
Colour Touch Screen with a large range of features |
Multiple Programmes |
Test programmes ,working programmes |
Main parts |
Equipped with pneumatic valves |
Stainless Steel installation and piping |
|
micro-printer recorder |
|
With stainless steel cart and trolley |
The autoclave steam sterilizer advantages:
Specifications:
Model |
MD-0.8 |
Door number |
Single door |
Door type |
Motorized Hinge Door |
Chamber volume |
800 liters |
Chamber Size |
61*91*145cm |
Overall Size |
145*190*179cm |
Net Weight |
1400kg |
Steam |
35Kg/cycle |
Water |
80Kg/cycle |
Power(KVA) |
3KVA |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Loading patterns |
Loading Baskets |
Loading trays |
|
Loading car and trolley |
Temperature Control: electronic temperature control system in the chamber through two
PT-100 -class A platinum - thermo resistors located at the chamber condensate discharge drain.
The sterilizer foresees a continuous inspection and cycle temperature certification system with
the placement of another PT100 sensor along with the sensor, whose measurement will be also
recorded in the printer.
It has a comparison system between the main temperature sensor and the reference sensor
alerting in cases of differences higher than the allowed at the sterilization phase. In this case,
the command will allow the definition of this sensor or of the one placed at drain, as the
responsible for the cycle control.
Chamber and Jacket pressure control: performed by electronic pressure transducers
manufactured in stainless steel, with electronic temperature compensation and absolute pressure
reading, regardless of the atmospheric pressure in the area where the equipment is installed.
The pressure transducers have output signal ranging from 4 to 20mA and precision of 0.5%
from the scale bottom . The indications are performed digitally through loading and unloading
panels in millesimal or centesimal of bar.
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400