Product Details:
Payment & Shipping Terms:
|
Application: | CSSD, Medical Centers , Operation Room | Temperature Rage: | 105°c To 134°c |
---|---|---|---|
Working Program: | Textiles,Instruments, Rubbers | Test Programs: | Bowie & Dick Test, Vacuum Test |
Sterilization Procedure: | Steam | Loading Type: | Front-Loading |
High Light: | horizontal sterilizer,Prevacuum Steam Sterilizer |
0.22μm Air Filter Horizontal Autoclaves Mechanical Vacuum Pump For Hospital
Quick Details
Material
Chamber | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Jacket | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Door internal side | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
|
Specifications
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.12V | 400*400*750 | 1100*1800*1250 | 700 | 14 | 215 | 2 |
MD-0.16V | 400*400*1000 | 1000*1800*1340 | 700 | 16 | 220 | 2 |
MD-0.20V | 400*400*1300 | 1000*1800*1640 | 750 | 18 | 225 | 2 |
MD-0.24V | 600*600*670 | 1200*2000*1010 | 800 | 20 | 230 | 2 |
MD-0.30V | 600*600*840 | 1200*2000*1180 | 850 | 22 | 235 | 2 |
MD-0.36V | 600*600*1000 | 1200*2000*1340 | 900 | 25 | 240 | 2 |
MD-0.45V | 600*600*1250 | 1200*2000*1590 | 980 | 27 | 250 | 2 |
MD-0.60V | 600*600*1670 | 1200*2000*2010 | 1100 | 30 | 260 | 3 |
Sterilization Cycles
Cycle No. | Cycle Name | Further Details |
1 | Instruments/Tools | 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
2 | Clothing | 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
3 | Liquid | 15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. |
4 | B-D Test | 3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
5 | Vacuum Leak Test | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
6 | User Programmable | All preset parameters can be resettable; Multiple customized programs can be set and stored by user. |
Vacuum Pump
A highly efficient liquid ring vacuum pump, mounted on vibration isolators for quiet operation, is provided to effectively remove air from the chamber. The vacuum pump is connected in series to assist air removal and protect the vacuum pump from excessive temperatures. The vacuum pump is protected with a low water alarm on the service water.
Air Filter
A 0.22um air filter is provided, for filtering of atmospheric air, entering the chamber. The air is used to equalize the chamber pressure at the end of the sterilization cycle. The filter separation efficiency is higher than 99,998% for particle size max. 0.22μm.
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400