Product Details:
Payment & Shipping Terms:
|
Chamber Volume: | 200 Liter | Pressure Vessel: | 304 Stainless Steel |
---|---|---|---|
Working Temperature: | 105°c To 134°c | Test Programs: | Bowie & Dick Test, Vacuum Test |
Application: | Laboratory | Control System: | PLC With Touch Operator Panel |
High Light: | horizontal sterilizer,Prevacuum Steam Sterilizer |
Chinese Pressure Vessel Certificate Vertical Sliding Door Horizontal Steam Sterilization Autoclave
Key Features
• For Laboratory applications
• Chamber volume 200 liter
• Single entry or pass-through versions
• Pressure vessel, jacket and door face manufactured from 304 grade stainless steel
• Effective temperature and pressure sensor which monitors chamber conditions throughout the cycle
• Efficient air removal using vacuum / pressure pulsing
• Short cycle times, meaning lower energy consumption
• Touchscreen control system with easy-to-use menu based screens.
• Internal data archiving
Automatic, Vertically Sliding Door (s)
The door is fully automatic in operation and is raised and lowered by a motor. Door operation is controlled via push buttons on the control panel. The door is automatically sealed. Doors can not be open during the cycle. The gasket is a silicon rubber ring. In the beginning of a process, the gasket is pressed against the rear face of the door by air. At the end of the process, the gasket is retracted by vacuum and the door on the unloading side is opened by a motor with gear box.
Specifications
Model |
MD-0.20V |
Chamber volume |
200L |
Chamber Size |
400*400*1300mm |
Overall Size |
1000*1800*1640mm |
Net Weight |
750kg |
Steam |
18Kg/cycle |
Water |
25Kg/cycle |
Power(KVA) |
2KVA |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Testing cylces |
Bowie & Dick test, vacuum test |
Control System
The PLC control system dedicated to controlling of Trans sterilizers, including:
• Digital inputs and outputs for sterilizer
• Control Analog measuring inputs
• COM ports for printer & PC communication
The controls all system functions, monitors system operations, both visually and audibly alerts the operator of cycle malfunctions and, on demand, provides visual indication of the chamber temperature and pressure.
Operation Panels
As default, the operator can access to the cycle selection, cycle start and door control.
Operators can only run type-tested cycles.
Access to other functions, such as running test cycles, setting parameters, calibration, service and maintenance is controlled using a predefined access levels preventing unauthorized access.
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400