                     Product Details: 
						                        
 Payment & Shipping Terms: 
							
  | 
                            
| Name: | Hospital Sterilizer | Volume: | 100Liters | 
|---|---|---|---|
| Door Type: | Vertical Sliding | Installation: | Recessed Wall Or Floor Standing | 
| Steam Generato: | Built In With Stainless Steel | Chamber Size: | 400*400*700mm | 
| Overall Size: | 1000*1800*1040mm | ||
| Highlight: | sterilization equipment for hospital,sterilising hospital equipment | 
			    	||
Vertical Sliding Door 100Liters Capacity Hospital CSSD Sterilizer With Micro Printer
Main Parameters
| 
			 Model  | 
			
			 Chamber Size  | 
			
			 Overall Size  | 
			
			 Net Weight  | 
			
			 Steam  | 
			
			 Water  | 
			
			 Power  | 
		
| 
			 W*H*D mm  | 
			
			 W*H*D mm  | 
			
			 Kg  | 
			
			 Kg/cycle  | 
			
			 Kg/cycle  | 
			
			 KVA  | 
		|
| 
			 MD-0.10V  | 
			
			 400*400*700  | 
			
			 1000*1800*1040  | 
			
			 650  | 
			
			 14  | 
			
			 15  | 
			
			 2  | 
		
| 
			 MD-0.16V  | 
			
			 400*400*1000  | 
			
			 1000*1800*1340  | 
			
			 700  | 
			
			 16  | 
			
			 20  | 
			
			 2  | 
		
| 
			 MD-0.20V  | 
			
			 400*400*1300  | 
			
			 1000*1800*1640  | 
			
			 750  | 
			
			 18  | 
			
			 25  | 
			
			 2  | 
		
| 
			 MD-0.24V  | 
			
			 600*600*670  | 
			
			 1200*2000*1010  | 
			
			 800  | 
			
			 20  | 
			
			 30  | 
			
			 2  | 
		
| 
			 MD-0.30V  | 
			
			 600*600*840  | 
			
			 1200*2000*1180  | 
			
			 850  | 
			
			 22  | 
			
			 35  | 
			
			 2  | 
		
| 
			 MD-0.36V  | 
			
			 600*600*1000  | 
			
			 1200*2000*1340  | 
			
			 900  | 
			
			 25  | 
			
			 40  | 
			
			 2  | 
		
| 
			 MD-0.45V  | 
			
			 600*600*1250  | 
			
			 1200*2000*1590  | 
			
			 980  | 
			
			 27  | 
			
			 50  | 
			
			 2  | 
		
| 
			 MD-0.60V  | 
			
			 600*600*1670  | 
			
			 1200*2000*2010  | 
			
			 1100  | 
			
			 30  | 
			
			 60  | 
			
			 3  | 
		
Benefit
- Unique non-stick door gasket
Specially formulated to eliminate sticking and to avoid door jamming
 
- Air-actuated gasket
Minimizes steam exposure to greatly extend gasket working life
- Whisper-quiet, integrated air compressor
Minimizes noise, eliminates need for facility air supply, supplies constant air pressure to gasket
- Side-mounted controls
Avoids steam exposure to electronics and extends touchscreen life.Front access swing-out assembly and magnetically attached side panels.Simplifies serviceability, assures access to all components
- Counterbalanced sliding door
Simplifies working footprint, lifts without the complexity of pneumatic or service-prone hydraulics
Description
Sliding door steam sterilizer simplifies chamber access with a sliding counterbalanced door
that seals safely against an air actuated non-stick gasket.
The non-stick gasket design provides a longer service life than a conventional steam-actuated
gasket.
The gasket is recessed into a precision-machined slot and will maintain a secure seal even in the event of a total utility loss. The gasket is easy to replace and does not require special tools or lubrication.
The door sealing mechanism includes redundancy for added security; a safety lock prevents
the door from opening if the chamber is under pressure.
Ergonomic benefits include a wide-grip handle and smooth, vertical open/close action on a counterbalanced assembly that is easy-to-operate with one-hand access.
Applications
Hospital CSSD department for instruments, garment and rubbers cap etc.
Competitive Advantage
Compact design, small space needed.
![]()
![]()
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400