Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
Home ProductsCSSD Sterilizer

Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve

China ZHANGJIAGANG MEDPHARM MACHINERY LTD. certification
China ZHANGJIAGANG MEDPHARM MACHINERY LTD. certification
It is worthy to cooperate with Medpharm again. Also, prompt action on after sales service left me a deep impression.

—— Manusawee Wareesuwan

I like the sterilizer here running in our factory,it is wonderful.It is fully made to my requirement.Before that I contact many suppliers but they can

—— Marina.Stolyrova

I'm Online Chat Now

Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve

Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve
Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve

Large Image :  Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve

Product Details:
Place of Origin: China
Brand Name: Medpharm
Certification: CE/SGS
Model Number: MD-1.0Y
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Price: Negotiation
Packaging Details: Solid plywood case suitable for long distance transportation
Delivery Time: 30 working days after received your payment
Payment Terms: T/T in advance, LC AT SIGHT
Supply Ability: 10 pcs per month
Detailed Product Description
Product Name: CSSD Sterilizer Certificate: CE/SGS
Sliding Door: Single Door Door Mechanism: Pneumatic Door Seal
Sterilization Media: Saturated Steam Filter Precise: 0.22um
Pressure And Temperature Transmitte: Danfoss PLC: Mitsubishi
High Light:

cssd hospital equipment

,

sterilising hospital equipment

   

Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve

 

Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve 0

 

Specification

 

Model

Chamber Size

Overall Size

Net Weight

Steam

Water

Power

W*H*D mm

W*H*D mm

Kg

Kg/cycle

Kg/cycle

KVA

MD-1.0Y

680*1180*1250

2200*2000*1660

1630

40

100

4

 

Program Parameter

 

Cycle name

Further details

Application

Instruments/Tools

3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.

Solid materials to be sterilized:

●Packaged instruments

●Empty glass containers

●Empty metal containers

Porous materials to be sterilized:

●Rubber articles

Clothing

3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.

Materials to be sterilized from which air can’t be easily displaced

●Textile

User Programmable

All preset parameters can be reset; Multiple customized programs can be set and stored by user.

Customized

Test programs

B-D Test

3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.

Test program

Vacuum Leak Test

Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.

Test program

 

 

 

                                                                                                                                                     

Description

 

Construction

 

The sterilizer has double walled (inner chamber & Jacket) type design, which allows preheating

of chamber by jacket steam. The chamber is constructed of heavy-duty stainless steel 304/316.

 

Doors

 

The Sterilizer is supplied with single door or double doors made of 304/316 S .S. The door has

provision, which prevents. Opening of door when the chamber is under pressure.

 

Multi-Port Main Operating Valve

 

To control from one point various phases of entire sterilization Cycle such as: Steam entry to the Chamber, Exhaust the chamber steam with selection of 2-speeds "Slow" or "Fast" depending upon the type of load; Vacuum drying of load by creating partial vacuum in chamber, break the vacuum and to attain atmospheric pressure;

 

Plug Screen in the Chamber (in front)

 

To prevent the choking of the discharge line with solids; It is easily removable for regular cleaning.

 

Thermostatic Steam Trap/Air Vent

 

Fitted in chamber discharge line for automatic removal of air and chamber condensate intermittently.

 

S.S. Perforated Bottom Shelf

 

In chamber, to avoid the load from coming in contact with condensate.

 

S.S. Baffle Plate

 

Fitted in the chamber in front of the steam inlet for proper distribution of steam in the chamber

and to avoid the entering steam from directly hitting onto the load.

 

Powerful Ejector

 

For creating partial vacuum in chamber

 

Self - Sterilizing Vacuum Dryer

 

Having a corrosive-resistant filter to admit only dry filtered hot air into the chamber to avoid

contamination of sterilized load.

 

High Speed type

 

Uses for urgent need of sterilization of instruments etc. near operation theater, Cycle time is

reduced by increasing the heating load of steam generator.

 

All other features will remain same Instrument Rack (Optional item for High Speed units), It is made of 304 SS & useful for loading & unloading of material into the chamber.

 

Applications

 

Sterilizers are suitable for Hospitals, clinics, Laboratory etc. They are designed for safe & efficient sterilization of various items such as wrapped or unwrapped goods, instruments & utensils etc.

 

Competitive Advantage

 

Confirm to below regulation

  • GB 150.1~GB 150.4 - 2011 Steel Pressure Vessel
  • GB/T 191- 2008 Pictorial Markings for Handling of Packages
  • GB 4793.1- 2007 Measurement, Control and Lab Safety Requirements of Electrical Equipment, Part 1: General Requirement
  • GB 9969.1- 1998 General Principles for Preparation of Instructions for Use of Industrial Products
  • GB/T 14710-2009 The Environmental Requirements and Test Methods for Medical Electrical Equipment
  • GB 18278- 2000 Sterilization of Health Care Products--Requirements for Validation and Routine Control--Industrial Moist Heat Sterilization
  • JB/T 4711- 2003 Coating, Shipping and Packing of Pressure Vessel
  • YY 0076-1992   Metal Parts Classification Technology Conditions of Coating
  • YY 0085.1-1992 Pulse Vacuum Pressure Steam Sterilizer
  • SFDA 2010 version GMP
  • Chinese Pharmacopoeia 2010
  • Supervision Regulation on Safety Technology for Fixed Type Pressure Vessel
  • ISPE, Volume 4, Water and Steam System, Edition 1, Jan. 2001

 

Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve 1

 

 

Brochure load down from here

Medpharm medical large steam autoclave brochure.pdf

Contact Details
ZHANGJIAGANG MEDPHARM MACHINERY LTD.

Contact Person: Ms. JULIET

Tel: +8613915466171

Send your inquiry directly to us (0 / 3000)